SST: physical ID incorrect for objects in logical block zero
Closed, ResolvedPublic

Description

In the SST object create function, the physical ID is not programmed correctly for objects stored in logical block zero. This can cause data loss when multiple create operations are interleaved with write operations.

jf549 created this task.Apr 24 2018, 3:44 PM
jf549 triaged this task as Normal priority.
jf549 closed this task as Resolved.Apr 27 2018, 3:08 PM

Resolved by the following patch:
https://review.trustedfirmware.org/#/c/43/